Features
-
System Parameter
-
General data
-
Features
-
System Parameter
-
General data
Technical Specs
-
Stacked installation
Easy to transport and install
-
Modular design
Strong scalability of system capacity
-
Real-time monitoring
Suitable for remote diagnosis and upgrade
-
High protection level
Support indoor & outdoor installation
Model | RHP7.0-G1 | RHP10-G1 | RHP14-G1 | RHP17-G1 |
---|---|---|---|---|
Battery distribution unit | RHP-BCU-G1 | |||
Battery Module | RHP-BAT37-G1:96V,37AH | |||
No. of battery modules | 2PCs | 3PCs | 4PCs | 5PCs |
Nominal capacity | 7.1kWh | 10.66kWh | 14.21kWh | 17.76kWh |
Usable energy | 6.75kWh | 10.12kWh | 13.50kWh | 17kWh |
Operating voltage range | 168 ~219V | 252 ~ 328V | 336 ~ 438V | 420 ~ 547V |
Nominal voltage | 192V | 288V | 384V | 480V |
Max. charge/ discharge current | 25A/25A | 25A/25A | 25A/25A | 25A/25A |
Model | RHP7.0-G1 | RHP10-G1 | RHP14-G1 | RHP17-G1 |
---|---|---|---|---|
Dimension (W*H*D) | 504*380*700mm | 504*380*900mm | 504*380*1100mm | 504*380*1300mm |
Weight | 105kg | 146kg | 187kg | 228kg |
Lifecycle | 6000 | |||
Max. operating altitude | 2000m | |||
Operating humidity | 0-95% | |||
Operating temperature | Charge:0-50℃;Discharge:-10-50℃ | |||
Communication method | CAN | |||
Protection level | IP54 | |||
Installation method | Stacking, Floor Mounting | |||
Max. expansion number | 4 |